home *** CD-ROM | disk | FTP | other *** search
- The following chart describes where you can find each of the appendices
- provided with LAN Inventory:
-
- APPENDIX CONTENTS FILE NAME
- A Equipment Database LIref.txt
- B Troubleshooting LIref.txt
- C Using Brequest Btrieve.txt
- D Btrieve Status Codes Btrieve.txt
- E NMS Smart-Launch Support NMS.txt
- F Introduction to Crystal Reports Crystal.txt
- G Using Crystal Reports Crystal.txt
- H Practical Crystal Reports Crystal.txt
-
- LIREF.TXT Headings:
-
- 10.0 Appendix A Equipment Database
- 10.1 Equipment Inventory Records
- 11.0 Appendix B Troubleshooting
- 11.1 Error Messages
-
-
- 10.0 Appendix A Equipment Database
-
- This appendix discusses and provides examples of the following:
-
- o equipment inventory record types and their contents
- o information collected by the EQUIP.EXE program
-
-
- 10.1 Equipment Inventory Records
-
- Equipment inventory records are displayed by choosing the Inventory command
- from the View menu.
-
- The detailed inventory information that displays for each record depends on
- the record type. Record types consist of file server, MAC, PC workstation,
- and spare parts. The fields displayed for each type are listed below:
-
- o Fields Displayed For File Servers
- - Computer Information (Serial Number, Network Operating System,
- CPU, Memory)
- - Volumes
- - Physical Drives
- - LAN Adapter Information
- - Software Applications
- - Miscellaneous Equipment
-
- o Fields Displayed For MACs
- - Computer Information (Appletalk Version, CPU, Finder Version,
- Floating Point Unit, Keyboard, Memory, Model, ROM Size, ROM Version,
- System Version)
- - Slot Adapter/Drivers
- - Monitors
- - Floppy Drives
- - Mounted Volumes
- - SCSI Devices
- - Software Applications
- - Miscellaneous Equipment
-
- o Fields Displayed For PC Workstations
- - Computer Information (Model, Bios, Bios Date, Brand, BUS, CMOS,
- Clock Frequency, CPU, Operating System and Version)
- - Mass Storage
- - Keyboard/Display
- - Ports
- - Network Adapter
- - Memory
- - Software Applications
- - System Files
- - Miscellaneous Equipment
-
- o Fields Displayed For Spare Parts
- - Computer Information (Memory, CPU, Serial Number, Network
- Operating System)
- -Miscellaneous Information
-
-
- 11.0 Appendix B Troubleshooting
-
- Appendix A provided information about LAN Inventory's equipment databases.
- This appendix provides a listing of LAN Inventory's error messages and their
- explanations.
-
- 11.1 Error Messages
-
- Add Inventory - This Field Cannot be Left Empty
- The Site field must contain information.
-
- Audit Not Completed On Site
- The audit was not successfully completed.
-
- Btrieve Error
- All Btrieve errors are reported by a number. Refer to Appendix D to
- discover the reason for the error.
-
- Cannot Copy File - Source File
- The source file names for saving the baseline may not be set
- properly; there may not be enough disk space; you may not have
- sufficient rights to the destination directory; or the files might
- be flagged as Read Only.
-
- Cannot Create File - Target File
- The target file(s) for saving the baseline could not be created.
- Check rights and disk space/directory entries.
-
- Cannot Delete a Pre-Defined Report
- The reports that are provided with BrightWorks cannot be deleted.
-
- Cannot Initialize Btrieve
- Btrieve failed to initialize; check available memory.
-
- Cannot Initialize Libraries
- DATALIB and/or WNCFS DLL's are missing. Check available memory.
-
- Cannot Re-Define this Report
- The reports that are pre-defined and provided with this product
- cannot be re-defined. Try saving the report under a different name.
-
- Could Not Access Shell Network Information
- Your network is not responding. You must reboot the machine and
- retry the operation..
-
- Could Not Create ID File
- The file that generates IDs for stand-alone equipment could not be
- created. Check that the diskette is not write protected.
-
- Could Not Login to Server
- The name/password you entered is invalid.
-
-
- Delete Unidentified Software - This Item is in the Transfer List -
- Delete it First.
- A software title that is included in the transfer list was selected
- to be deleted. It must first be removed from the transfer list.
-
- Entry Is Reserved for Fusion Use, Cannot Edit Entry
- Some Categories, Classes and Types are reserved for BrightWorks use
- and cannot be edited or deleted. The following fields cannot be left
- blank:
- Category
- Class
- Manufacturer
- Product Name
- For PC and MAC Software Lists, the following fields cannot be left
- blank:
- Product Name
- File Name/File Creator
- File Size
- Version Number
-
- Error # Deleting Report
- The system encountered the specified error attempting to delete a
- report.
-
- Error #: Server "server name"
- A network error occurred on the specified server. Consult NetWare
- documentation for a description of the error number.
-
- Error Allocating Global Memory
- This product could not allocate extra memory to store system files.
-
- Error Reading Audit Parameters
- The file WAUDCFG.DAT, which contains the Audit parameters, could not
- be read.
-
- Error Removing Alert Timer
- The system was unable to remove the timer for alerting.
-
- Error Removing Audit Timer
- The system was unable to remove the timer for an automatic audit.
-
- Field Type Do Not Match
- The BrightWorks field format (character or numeric) and the field to
- be imported format differ.
-
- File 'WEQTRNA.DXT' Could Not be Found
- The path specified to load stand-alone equipment from does not
- contain this file, which is needed for the stand-alone hardware.
-
- Invalid Hour Entry
- Entry must be in the range 12 AM - 12 PM.
-
- Invalid Minutes Entry
- Entry must be in the range 0 - 59.
-
- Local Site Already Has This Name
- The name you entered is already assigned to the local site. Select
- a different Site name.
-
- Local Site Cannot be Deleted
- The Site name you wish to delete is the name of the local site and
- cannot be deleted.
-
- Local Transaction Files Could Not be Found
- The directory from which BrightWorks is running does not have the
- local transaction files to which stand-alone information should be
- loaded. To solve this, you need a search drive set up to BrightWorks.
-
- Login Name Cannot Be Left Empty
- The Login Name field cannot be empty when specifying access to a
- server.
-
- Macintosh Update Aborted
- The Macintosh update was aborted at user's request.
-
- Memory Allocation Error
- The system was unable to allocate memory for the specified operation.
- Close one or more applications and try the operation again.
-
- NetWare Error
- Could not attach to server due to one of the following:
- a hardware error
- the 8 server slots are in use
- the maximum number of users for the server has been reached
-
- No Data For This Report
- There was no data satisfying the filtering conditions set in the
- report.
-
- No Fields Selected
- At least one field must be selected to print for the Custom Report
- or the Detailed Equipment Report.
-
- No Fileservers Specified
- No servers were included in the Audit.
-
- No Sites Specified
- No sites were specified in the Scope of Audit.
-
- Not Enough Disk Space Available
- The collector diskette does not have the space needed for stand-alone
- files.
-
- Option Available Only from Menu Bar (Delete Component)
- When creating new equipment components, bringing up the list of
- components, the user cannot delete an existing component.
-
- Path Name Cannot be Left Empty - Edit Site
- The Path Name must contain information when editing sites.
-
- Path Name is Already in Use
- Sites must be assigned unique path names.
-
- Product has Not been Installed
- BrightWorks needs to be properly installed following the instructions
- in Chapter 2 of this manual. If the program has been properly
- installed, run CIN.EXE to re-enable BrightWorks.
-
- Required Fields Are Missing
- One or more of the fields that uniquely identify a workstation are
- missing: site - nodeid_1 - nodeid_2 - name.
-
- Selected Fields Will Not Fit on Page
- Using the current page set-up, the fields that have been selected
- for printing will not fit across the page. Either select a smaller
- font, set a smaller maximum field width, select the "One Field Per
- Line" option, or select fewer fields to print.
-
- Server Update Aborted
- Server update aborted at user's request.
-
- Server Update Not Completed
- File Server information was not updated in the transaction file due
- to one of the following reasons:
- The file WSERVER.DAT (containing the list of servers) could
- not be read
- No servers were included in the Scope of Audit
- No unique ID could be determined for that server
-
- Site Name Cannot be Left empty - edit site
- When editing a Site, the Site field must contain information.
-
- Source File Not Specified
- When backing up the baseline, the source baseline file must be
- specified.
-
- Supervisor Rights Required
- Supervisor rights or equivalent are needed to run an audit on a
- server.
-
- System Files To Audit - This is Not a Valid File Name
- A valid file name is up to 14 characters long; the period is
- required.
-
- The Transaction File Is Empty
- The transaction file is empty due to one of the following reasons:
- EQUIP has not been run
- MAC files were not loaded into the transaction files
- Stand-alone equipment has not been loaded
- The file server information update failed
-
- There is no Audit Selected
- When running the Audit Results Report, a specific audit must be
- selected.
-
- Transfer Unid Software as Group - Base Name / Version No. Already In Use
- The combination of base name / version no is in use by another
- software title.
-
- Unable to Configure Printer
- The system was not able to initialize the printer. Make sure that a
- printer is set up for Windows and the correct driver is present in
- the Windows system directory. If necessary, delete the file WLAI.INI
- from the Windows directory and try to print again.
-
- Unable to Create Timer Window
- The system was unable to create the timer window for an automatic
- audit or alerting. This is probably due to low memory or system
- resources. Close one or more applications and try the operation again.
-
- Unable to Create Window
- The system was unable to create a window. This is probably due to
- insufficient memory or system resources. Close one or more
- applications and try the operation again.
-
- Unable To Determine Unique ID
- The file that stores the unique file server ID, which is in the
- SYS:SYSTEM dir as a hidden file called LAIID.CFG, could not be
- created or opened. If the hidden file is zero bytes, delete it and
- try again.
-
- This message might also appear if the number of files in use exceeds
- the maximum number specified in the CONFIG.SYS file (usually when
- the user is running other Windows or DOS applications).
-
- Unable to Initialize NetWare Structures
- Your network is not responding. You must reboot the machine and
- retry the operation.
-
- Unable to Initialize Timer
- The system was unable to initialize the internal timer used to track
- automatic audits and alerts. This is probably caused by other
- applications using all system timers. Close an application that uses
- a timer and try the operation again.
-
- Unable to Open Export File
- The user must have write/create rights, and there must be enough
- disk space to create the export file. If you are trying to export to
- a root directory, try exporting to a sub-directory instead.
-
- Unable to Open File
- The system was not able to open the specified file. Make sure that a
- valid directory was specified and that the user has sufficient
- rights to this directory.
-
- Unable to Open Import File
- The file selected to be imported could not be opened. The file could
- be corrupted.
-
- Unable to Open Report Files
- The system was not able to open the files which contain the data
- being reported.
-
- Unable to Retrieve Report Information
- The system was not able to open or read one or more of the files
- required to run the specified report. Before creating reports, you
- must run an audit and have data in your baseline.
-
- Unable to Write to Temporary File
- There is not enough disk space for the temporary file. Free up some